# Laboratory fume hoods

> LabAirTec fume cupboards (fume hoods): ducted units with a Renggli AG EN 14175 declaration and the ductless LabAirTec green. Quotation in 1 to 5 days.

![Renggli laboratory fume hood with a sliding sash and a control panel in a laboratory](https://www.renggli.pl/m/dygestoria-rozszerzone-5x4__h1560f.webp)

A laboratory fume cupboard, known in the US as a fume hood, is a ventilated enclosure that draws vapours, gases and dust away from the operator and removes them through a duct or a filter. We supply ducted LabAirTec fume cupboards and the ductless LabAirTec green, and the Renggli AG bench models T120, T150 and T180 have EN 14175-3 type-test reports from the independent Tintschl laboratory in Erlangen. Ducted units come with their extract ducts but without the fan, and we prepare a standard quotation within 1 to 5 days.

## What is a laboratory fume hood and how does it work? {#what-is-a-laboratory-fume-hood-and-how-does-it-work}

A **laboratory fume hood** (also known as a fume cupboard or chemical fume extractor) is an enclosed workstation with forced airflow that draws vapours, gases and dust away from the working area before they reach the operator. Air from the room enters through the open sash of the chamber at 0.3 to 0.5 m/s, and slots in the rear wall carry it to the building's ventilation system or through a filter. The chamber is kept under slight negative pressure, so contaminants cannot escape. For more on the operating principle, see our guide on [what a fume hood is](https://www.renggli.pl/en/blog/what-is-a-laboratory-fume-hood).

In the UK and Ireland the usual name is **fume cupboard**; in the US, and in most international catalogues, it is **fume hood**. Both describe the same enclosure, and the European standard EN 14175 uses the term fume cupboard. You will also see “chemical fume hood”, “lab fume cupboard” and the one-word spelling “fumehood”, which is not a technical term. In German-speaking countries the same unit is called a Laborabzug or Digestorium.

## EN 14175: the parameters a fume hood must meet {#en-14175-the-parameters-a-fume-hood-must-meet}

Fume cupboards are covered by the European standard **EN 14175**, published in the UK as BS EN 14175. Part 2 sets the safety and performance requirements, part 3 the type-test methods, including a tracer-gas containment test, part 4 the on-site tests after installation and part 6 variable air volume (VAV) fume cupboards. Recirculatory filtration fume cabinets have a separate standard, EN 17242. In day-to-day use the figure that matters most is the face velocity at the working sash opening, typically 0.3 to 0.5 m/s with the sash raised to a working height of 500 mm. The standards for laboratory furniture and fume cupboards, and the Renggli products they relate to, are listed on our [standards and certificates](https://www.renggli.pl/en/standards) page.

LabAirTec fume hoods operate with a VAV (Variable Air Volume) system, which matches the volume of extracted air to the sash position. A flow sensor accurate to 0.01 m/s triggers visual and audible alarms when the velocity falls below the safety threshold. Our article on [how to calculate fume hood airflow](https://www.renggli.pl/en/blog/fume-hood-efficiency-how-to-calculate-airflow) shows how to work out the air volume required for a room. All laboratory furniture standards, together with the products they apply to, are collected on the [standards and certificates](https://www.renggli.pl/en/standards) page.

## Ducted or ductless (filtered) fume hood? {#ducted-or-ductless-filtered-fume-hood}

The choice depends on whether the room has an extract duct and which substances go into the chamber. A [ducted fume hood](https://www.renggli.pl/en/offer/fume-hood/extraction-fume-hoods) connects to central ventilation with a capacity of 400 to 1200 m³/h per workstation; it discharges air outside the building and is suitable for a wide range of reagents. We supply the fume cupboard with its extract ducts, ready for connection; the extract fan is not part of the delivery and is planned as part of the building's ventilation system. The [LabAirTec „green” ductless fume hood](https://www.renggli.pl/en/offer/fume-hood/non-extraction-fume-hood) cleans the air with a carbon or HEPA filter and returns it to the room, so it needs no ducting. It works well for repeatable processes with a known, limited set of substances.

## Types of laboratory fume hood in our range {#types-of-laboratory-fume-hood-in-our-range}

Two parameters determine the design: the space available and the required extraction capacity. Eight fume hood types, including ones outside our range, are scored in our [laboratory fume hood comparison](https://www.renggli.pl/en/guides/fume-hood-types-compared). Fume hood suppliers operating in Poland, Renggli included, are compared in our [fume hood ranking](https://www.renggli.pl/en/guides/fume-hood-manufacturers-poland). Our range covers four main variants:

- **Free-standing fume hoods**: most commonly in widths of 1200, 1500 and 1800 mm, with a ventilated chemical cabinet beneath the worktop.
- **Benchtop fume hoods**: compact chambers mounted on existing worktops where space is limited.
- **Walk-in fume hoods**: for tall equipment standing at floor level, in widths from 900 to 3000 mm.
- **Double-chamber units**: two independent processes in one unit.

The order of decisions when buying (substances, dimensions, services, controls) is set out in our guide on [how to choose a fume hood](https://www.renggli.pl/en/blog/laboratory-fume-hood-how-to-choose).

### Working chamber equipment {#working-chamber-equipment}

Services are routed into the chamber, while valves and switches are placed on an external panel so that the operator can shut them off without reaching inside. The standard specification includes:

- workstation lighting,
- water supply and drainage with a small ceramic or polypropylene laboratory sink set into the worktop,
- gas supply controlled by valves on the panel (ready-made [fume hood sets](https://www.renggli.pl/en/offer/laboratory-armature-and-valves/fume-hood-fittings) of taps and valves),
- 230 V electrical sockets rated IP44,
- a sliding sash of ESG toughened safety glass, 4 to 6 mm thick, on acid-resistant cables with counterweights and a stop at a height of 500 mm.

## Fume hood chamber and worktop materials {#fume-hood-chamber-and-worktop-materials}

The chamber and worktop material is selected to suit the reagents and temperatures involved. Our standard fume hoods are available in five variants:

- **large-format ceramic (LCT)**: resistant to concentrated acids, including sulphuric and nitric, and to temperatures of 1000 to 1200°C,
- **polypropylene (PP)**: for work with hydrofluoric acid,
- **stainless steel**: for biological and pharmaceutical laboratories, as it is easy to disinfect,
- **epoxy resin**: resistant to concentrated alkalis and inorganic acids (except hydrofluoric), with a worktop load capacity of up to 200 kg/m²,
- **HPL laminate**: an economical choice for standard analyses.

The [laboratory worktops](https://www.renggli.pl/en/offer/laboratory-countertops) on the benches next to the fume hood come in the same materials, so the entire workstation can share one resistance class.

## Specialist fume hoods: hydrofluoric acid, Ex zones, perchloric acid {#specialist-fume-hoods-hydrofluoric-acid-ex-zones-perchloric-acid}

A standard chemical fume extractor is not suitable for hydrofluoric acid (HF) or for potentially explosive atmospheres (ATEX). For these applications we offer special versions:

- **explosion-proof (Ex) fume hoods** for work with flammable substances in potentially explosive zones,
- **hydrofluoric acid fume hoods** with a chamber made entirely of polypropylene.

Perchloric acid is a separate case: its vapours deposit explosive perchlorates in the duct, so the chamber and duct must be fitted with a washdown system. The requirements are described in our guide to selecting [a perchloric acid fume hood](https://www.renggli.pl/en/blog/laboratory-perchloric-acid-fume-hood-selection).

## Fume hoods in the school laboratory {#fume-hoods-in-the-school-laboratory}

In a school chemistry laboratory, a fume hood protects the teacher and pupils during demonstrations involving gases and vapours. What matters is a chamber that is visible from several sides, a sash lock, a simple control panel and a position in the room that does not block the board. For more on what to look for, see our article on choosing [a fume hood for a school laboratory](https://www.renggli.pl/en/blog/fume-hood-in-the-school-workshop-what-to-look-for-when-choosing).

## Fume hood vs laminar flow cabinet: key differences {#fume-hood-vs-laminar-flow-cabinet-key-differences}

A fume hood protects the operator from chemical vapours: it draws in air from the room and removes it along with the contaminants. A laminar flow cabinet protects the sample from contaminants in the surroundings by supplying it with sterile air. A biological safety cabinet (BSC) protects the product, the operator and the environment from biological agents. These units are not interchangeable.

## Fume hood maintenance and inspections {#fume-hood-maintenance-and-inspections}

A fume hood retains its protective properties only if it is regularly cleaned and checked. Day-to-day care requires no more than:

- cleaning the inside of the chamber with a soft cloth and mild detergent (abrasive products damage the worktop surface),
- neutralising surfaces and rinsing them with distilled water after work with aggressive substances,
- removing chemical deposits before they cause corrosion or an uncontrolled reaction.

Our guide on [how to maintain a fume hood](https://www.renggli.pl/en/blog/how-to-maintain-laboratory-fume-hood-step-by-step) covers this step by step.

### Regular technical inspections {#regular-technical-inspections}

In Great Britain the interval is set in law: [regulation 9 of the COSHH Regulations](https://www.legislation.gov.uk/uksi/2002/2677/regulation/9) requires local exhaust ventilation to be thoroughly examined and tested at least once every 14 months, and HSE guidance [HSG258](https://www.hse.gov.uk/pubns/books/hsg258.htm) classes a fume cupboard as a partial enclosure of that kind. In Germany, [DGUV Information 213-850](https://res.jedermann.de/data/downloads/DGUV-Information_213-850_Gesamtdokument.pdf) requires a test at least once a year. A typical examination covers:

- **airflow measurement**: face velocity at the sash and sensor calibration,
- **installations**: tightness of the water, drain and gas connections and the condition of the electrical sockets,
- **filters**: inspection and replacement of carbon or HEPA cartridges in filtered models.

## What the price of a Renggli fume hood depends on {#how-much-does-a-laboratory-fume-hood-cost}

The price of a fume hood is set for a specific configuration, because it depends on several factors at once:

- **type and width**: benchtop, free-standing 1200 to 1800 mm, walk-in or double-chamber,
- **chamber and worktop material**: HPL laminate, epoxy resin, ceramic, stainless steel or polypropylene,
- **airflow control**: constant extraction or a VAV system with sensor and alarm,
- **special version**: Ex, HF, perchloric acid, or carbon or HEPA filtration,
- **services and equipment**: water, gases, vacuum, sockets, chemical cabinet beneath the worktop.

Prices from Polish price lists and awarded public tenders are collected in our guide [how much does a fume hood cost](https://www.renggli.pl/en/guides/fume-hood-price). At Renggli we usually price a fume hood together with the rest of the workstation, meaning the [laboratory furniture](https://www.renggli.pl/en/offer/laboratory-furniture-systems), worktops and laboratory taps and valves, because these determine the connections and the volume of air in the room.

## Subcategories

- [Ducted fume hood](https://www.renggli.pl/en/offer/fume-hood/extraction-fume-hoods)

## Products

- [LabAirTec green ductless fume cupboard](https://www.renggli.pl/en/offer/fume-hood/non-extraction-fume-hood)

**Not sure which fume hood is best for your lab?**

Contact our experts for professional advice and to choose the optimal solution.

[Contact an Expert](https://www.renggli.pl/en/contact)

![](https://www.renggli.pl/m/legacy-images-pages-offer-fume-hood-dygestorium-STV9wSwg6ee6wGNefTHgUKEBtDLWLU__h1260f.webp)

- **Air Volume Flow Control**: The airflow from the fume hood is maintained at a constant level, ensuring greater safety and cost reduction.
- **Motion Sensor**: The motion sensor closes the front window of the fume hood when no user is present, ensuring safety and cost savings.
- **Fume Hood Front Frame**: Control functions and the Bypass system are integrated into the frame, facilitating media installation and maintenance. Modern design.
- **Air Extraction Module**: The patented system increases airflow efficiency, improves emission removal, and simplifies module disassembly for decontamination.
- **Monitoring and Control**: An easy-to-use monitoring system at eye level provides intuitive control and enhances user safety.
- **Bypass System**: The Bypass system with air inlets ensures laminar flow, window regulation, reduces costs, and increases safety.
- **Automatic Front Restrictor**: Airflow control through window position and automatic closure significantly reduces operating costs.
- **Media Drawer**: The media drawer ensures safe installation and use, contains control valves, and is easily removable for upgrades.
- **Optical Sensor**: The front window stops when an obstacle is detected and opens hands-free when the user’s hands are occupied.
- **Active Air Inlet**: Fans in the front aluminum frame actively support the airflow.

## Fume cupboard certificates and declaration

- **Fume cupboard T120 (1200 mm)** (Type test EN 14175-3)
  Issued by: Tintschl BioEnergie und Strömungstechnik AG, Erlangen; Reference: FCS/EN/93/2006; Test date: 12 June 2006; Issued: 11 July 2014; Exhaust airflow: 480 m³/h; Face velocity: 0.34 m/s
  [Certificate](https://mom5efytyj47lt9h.public.blob.vercel-storage.com/renggli-certyfikat-en-14175-3-dygestorium-t120-1200-v1.pdf) (PDF · 188 kB · English, Polish), [Test report](https://mom5efytyj47lt9h.public.blob.vercel-storage.com/renggli-raport-badan-en-14175-3-dygestorium-t120-1200-v1.pdf) (PDF · 798 kB · English)
- **Fume cupboard T150 (1500 mm)** (Type test EN 14175-3)
  Issued by: Tintschl BioEnergie und Strömungstechnik AG, Erlangen; Reference: FCS/EN/109/2006; Test date: 14 November 2006; Issued: 11 July 2014; Exhaust airflow: 600 m³/h; Face velocity: 0.27 m/s
  [Certificate](https://mom5efytyj47lt9h.public.blob.vercel-storage.com/renggli-certyfikat-en-14175-3-dygestorium-t150-1500-v1.pdf) (PDF · 199 kB · English, Polish), [Test report](https://mom5efytyj47lt9h.public.blob.vercel-storage.com/renggli-raport-badan-en-14175-3-dygestorium-t150-1500-v1.pdf) (PDF · 868 kB · English)
- **Fume cupboard T180 (1800 mm)** (Type test EN 14175-3)
  Issued by: Tintschl BioEnergie und Strömungstechnik AG, Erlangen; Reference: FCS/EN/110/2006; Test date: 20 November 2006; Issued: 11 July 2014; Exhaust airflow: 720 m³/h; Face velocity: 0.27 m/s
  [Certificate](https://mom5efytyj47lt9h.public.blob.vercel-storage.com/renggli-certyfikat-en-14175-3-dygestorium-t180-1800-v1.pdf) (PDF · 210 kB · English, Polish), [Test report](https://mom5efytyj47lt9h.public.blob.vercel-storage.com/renggli-raport-badan-en-14175-3-dygestorium-t180-1800-v1.pdf) (PDF · 796 kB · English)
- **Renggli AG declaration of conformity: Euro II and LabAirTec fume cupboards (2015)** (EN 14175)
  Manufacturer's declaration of conformity with EN 14175, parts 1 to 6, issued on 6 February 2015.
  Issued by: Renggli AG, Rotkreuz; Issued: 6 February 2015
  [Declaration of conformity](https://mom5efytyj47lt9h.public.blob.vercel-storage.com/renggli-ag-deklaracja-zgodnosci-dygestoria-euro-ii-labairtec-2015-v1.pdf) (PDF · 141 kB · German)

## Models with an EN 14175-3 type test report

Renggli AG bench fume hoods: width, airflow and face velocity from the type test reports

| Model | Width (mm) | Airflow (m³/h) | Face velocity (m/s) | Test report |
| --- | ---: | ---: | ---: | --- |
| T120 | 1200 | 480 | 0.34 | [FCS/EN/93/2006](https://mom5efytyj47lt9h.public.blob.vercel-storage.com/renggli-raport-badan-en-14175-3-dygestorium-t120-1200-v1.pdf) |
| T150 | 1500 | 600 | 0.27 | [FCS/EN/109/2006](https://mom5efytyj47lt9h.public.blob.vercel-storage.com/renggli-raport-badan-en-14175-3-dygestorium-t150-1500-v1.pdf) |
| T180 | 1800 | 720 | 0.27 | [FCS/EN/110/2006](https://mom5efytyj47lt9h.public.blob.vercel-storage.com/renggli-raport-badan-en-14175-3-dygestorium-t180-1800-v1.pdf) |

The type tests were carried out by the independent Tintschl laboratory in Erlangen; the certificates were issued on 11 July 2014. The report number opens the PDF report, and the certificates are in the documents section below.

## Questions about fume cupboards and fume hoods

**What is a fume hood?**

A fume hood (in the UK a fume cupboard) is an enclosed laboratory workstation with forced airflow. It draws vapours, gases and dust away from the working area before they reach the operator and discharges them through a duct or a filter. The requirements for ducted fume cupboards are set out in EN 14175, published in the UK as BS EN 14175. How it works and the main types are explained in our article [what is a fume cupboard](https://www.renggli.pl/en/blog/what-is-a-laboratory-fume-hood).

**How does a fume hood work?**

A fan creates a slight negative pressure in the chamber, so air from the room flows in through the open sash at 0.3 to 0.5 m/s. Slots in the rear wall extract both light and heavy vapours, and the air is discharged outside the building or passed to a filter. The VAV system matches the air volume to the sash position, and a sensor raises an alarm if the airflow drops.

**Fume hood or fume cupboard: which term is correct?**

Both. **Fume cupboard** is the British term and the one EN 14175 uses; **fume hood** is the American term and the one most catalogues use. Suppliers also write “chemical fume hood” or “lab fume cupboard”. In Germany the unit is a **Laborabzug**, and in Austria it is often called a **Digestorium**.

**What is the difference between a ducted and a ductless fume cupboard?**

A ducted fume cupboard is connected to an extract duct and discharges the contaminated air outside the building, so it copes with changing substances and larger quantities. A ductless fume cupboard (recirculating, filtered) passes the air through filters and returns it to the room; it suits repeatable work with a known, limited list of substances, and its filters must match those substances. EN 14175 covers ducted fume cupboards and EN 17242 covers recirculatory filtration fume cabinets. We offer both: the [ducted LabAirTec](https://www.renggli.pl/en/offer/fume-hood/extraction-fume-hoods) and the [ductless LabAirTec green](https://www.renggli.pl/en/offer/fume-hood/non-extraction-fume-hood).

**What is the difference between laboratory extraction and a fume hood?**

A fume hood is an enclosed chamber with a sash that complies with EN 14175 and protects the operator with its entire enclosure. Laboratory extraction is a broader term: it also covers extraction arms and hoods above the workstation, which capture vapours at a single point only. Both solutions are compared in our article on [laboratory extraction vs fume hoods](https://www.renggli.pl/en/blog/laboratory-extractor-and-fume-hood-what-is-the-difference).

**What sizes do fume hoods come in?**

Free-standing fume hoods are most often 1200, 1500 or 1800 mm wide. The Renggli AG bench fume cupboards T120, T150 and T180 come in these three widths, and their [EN 14175-3 type-test reports](https://www.renggli.pl/en/downloads) give airflows of 480, 600 and 720 m³/h at face velocities of 0.34, 0.27 and 0.27 m/s. Depth and height depend on how the chamber, worktop and base cabinet are configured.

**How much does a fume hood cost?**

Fume hood prices from Polish price lists and awarded public tenders are collected in our guide [how much does a fume hood cost](https://www.renggli.pl/en/guides/fume-hood-price). We price Renggli fume hoods for a specific configuration and prepare a standard quote in 1 to 5 days.

**What warranty comes with a fume cupboard?**

Fume cupboards come with a 24-month warranty, which can be extended for an additional fee. Our service responds within 48 hours, and we carry out inspections and repairs after the warranty period as well. The exact scope for a given order is stated in the quote.

**Is the extract fan included with the fume cupboard?**

No. We supply the fume cupboard with its extract ducts, ready for connection; the extract fan is not part of the delivery and is planned as part of the building's ventilation system. Where no duct can be run, a ductless fume cupboard with a filter is used instead.

**How often must a fume cupboard be tested?**

In Great Britain at least once every 14 months: [regulation 9 of COSHH](https://www.legislation.gov.uk/uksi/2002/2677/regulation/9) sets this maximum for local exhaust ventilation, and HSE guidance HSG258 treats a fume cupboard as a partial enclosure of that kind. In Germany DGUV Information 213-850 requires a test at least once a year. The examination measures the face velocity at the sash and checks the fan, the extract system, the sensors and alarms and, in filtered models, the filters. Repeat it after any change to the room ventilation or after the fume cupboard is moved. Who may carry out each test and what the report should show is covered in our guide to [fume cupboard testing](https://www.renggli.pl/en/guides/fume-cupboard-testing).

**How do you choose a fume hood manufacturer?**

Ask for a type-test report to EN 14175-3 for the model you are buying, and check its date. Also ask about on-site testing to EN 14175-4 after installation, what the delivery includes (ducts, fan, airflow control), how long a quotation takes and whether the service includes an inspection at least once a year. We publish the type-test reports for the Renggli AG models T120, T150 and T180 from 2006 and the Renggli AG manufacturer's declaration from 2015 on the [downloads](https://www.renggli.pl/en/downloads) page.