title: "Laboratory cabinets"
description: "Renggli chemical safety cabinets: fire-resistant 30 and 90 minute models to EN 14470-1, acid and alkali cabinets to EN 16121, ventilated cabinets with filters."
canonical_url: "https://www.renggli.pl/en/offer/safety-storage-cabinets"
language: "en"
alternates:
  pl: "https://www.renggli.pl/pl/oferta/szafy-ognioodporne.md"
  de: "https://www.renggli.pl/de/angebot/sicherheitsschraenke.md"
  uk: "https://www.renggli.pl/uk/propozycja/spetsializovani-shafy.md"
  lt: "https://www.renggli.pl/lt/pasiulymas/specializuoti-saugumo-spintos.md"
---

# Laboratory cabinets

> Renggli chemical safety cabinets: fire-resistant 30 and 90 minute models to EN 14470-1, acid and alkali cabinets to EN 16121, ventilated cabinets with filters.

![Double-door fire-resistant chemical cabinet in a laboratory](https://www.renggli.pl/m/szafy-laboratoryjne-rozszerzone-5x4__h1560f.webp)

Laboratory chemical storage cabinets are enclosed units for storing reagents safely: fire-resistant safety storage cabinets for flammable liquids to EN 14470-1, cabinets for acids and alkalis to EN 16121, and ventilated chemical cabinets with a filter. We help you choose the class and model to suit the substances and the room.

## Which chemical storage cabinet should you choose? {#which-chemical-storage-cabinet-should-you-choose}

The type of cabinet depends on what it will hold. Three questions are enough:

1. **Are you storing flammable liquids** (solvents, alcohols, fuels)? You need a fire-resistant safety storage cabinet to EN 14470-1, rated at 30 or 90 minutes.
2. **Are you storing acids, alkalis or other corrosive but non-flammable substances?** A corrosion-resistant chemical storage cabinet for non-flammable substances to EN 16121 and EN 16122 is sufficient.
3. **Do the reagents give off vapours, with no extraction duct in the room?** The solution is a ventilated chemical cabinet with its own filter.

Our guide to [the storage of hazardous substances](https://www.renggli.pl/en/blog/storage-of-hazardous-substances-in-the-laboratory) covers the storage rules in more detail.

## 30-minute and 90-minute fire-resistant safety storage cabinets to EN 14470-1 {#30-minute-and-90-minute-fire-resistant-safety-storage-cabinets-to-en-14470-1}

A fire-resistant safety storage cabinet (safety cabinet) protects flammable liquids from an external fire for the time stated in its type designation: EN 14470-1 defines types of 15, 30, 60 and 90 minutes. In a fire, the doors close automatically and valves in the air ducts shut off the airflow.

- [30-minute fire-resistant safety storage cabinets](https://www.renggli.pl/en/offer/safety-storge-cabinets/specialized-safety-cabinets-30m): K, Q and S series, for smaller quantities of flammable liquids.
- [90-minute fire-resistant safety storage cabinets](https://www.renggli.pl/en/offer/safety-storge-cabinets/specialized-safety-cabinets-90m): the highest class in the standard, K, Q and S series models, for locations holding larger quantities of solvents.

We explain what the symbols on the cabinet's rating plate mean in our article on reading [cabinet markings and fire resistance class](https://www.renggli.pl/en/blog/laboratory-cabinet-markings-fire-resistance-class).

## Cabinets for acids and alkalis to EN 16121 and EN 16122 {#cabinets-for-acids-and-alkalis-to-en-16121-and-en-16122}

A cabinet for acids and alkalis has no fire resistance, but its interior is corrosion-resistant and its shelves have spill trays. EN 16121 and EN 16122 apply to storage furniture: the first sets out requirements for safety, strength, durability and stability, the second the methods for testing them. Our range of [cabinets for acids and alkalis](https://www.renggli.pl/en/offer/safety-storge-cabinets/chemical-storage-cabinets) comprises the SL-Classic, the under-worktop SL-Classic-UB and the CS-Classic. We explain why acids are not stored next to alkalis in our article on organising [the storage of acids and alkalis](https://www.renggli.pl/en/blog/storage-of-acids-and-bases).

## Ventilated chemical cabinets with a filter {#ventilated-chemical-cabinets-with-a-filter}

A [ventilated chemical cabinet](https://www.renggli.pl/en/offer/safety-storge-cabinets/ventilated-cabinets) has a filter-fan unit with an activated carbon filter on top, so it does not need to be connected to the building's ventilation system. The carcass, made of chipboard bonded to polypropylene, withstands acids, alkalis and moisture, and the pull-out shelves have polypropylene spill trays.

## Cabinet ventilation: when to connect it {#cabinet-ventilation-when-to-connect-it}

Fire-resistant safety storage cabinets and cabinets for acids have built-in air ducts that can be connected to an extraction system. The connection removes vapours from the interior before they can escape into the room when the doors are opened. Model data sheets state the recommended extraction rate: for example, a 1200 mm wide SL-Classic cabinet needs 31 m³/h, which equals 30 air changes per hour. Whether a connection is necessary is determined by the risk assessment for the substances stored. Industrial gas cylinders require a separate cabinet to EN 14470-2; we set out the requirements in our article on how to install [a gas cylinder cabinet](https://www.renggli.pl/en/blog/gas-cylinder-cabinet-safety-ventilation-requirements) safely.

## How much does a fire-resistant safety storage cabinet cost? {#how-much-does-a-fire-resistant-safety-storage-cabinet-cost}

The price of a cabinet depends on several features, so we provide it in a quotation for the model you select:

- **fire resistance class**: 30 or 90 minutes;
- **dimensions**: tall, low or under-worktop cabinet, single-door or double-door;
- **doors**: hinged or folding, with a self-closing mechanism and hold-open lock;
- **interior fittings**: shelves, drawers, spill sumps, spill trays;
- **ventilation**: prepared for connection to an extraction system, or fitted with a filter.

## Subcategories

- [Ventilated cabinets](https://www.renggli.pl/en/offer/safety-storage-cabinets/ventilated-cabinets)
- [90-minute safety cabinets](https://www.renggli.pl/en/offer/safety-storage-cabinets/specialized-safety-cabinets-90m)
- [30-minute safety cabinets](https://www.renggli.pl/en/offer/safety-storage-cabinets/specialized-safety-cabinets-30m)
- [Cabinets for non-flammable chemicals](https://www.renggli.pl/en/offer/safety-storage-cabinets/chemical-storage-cabinets)

## Frequently asked questions about chemical storage cabinets

**What is the difference between a 30-minute and a 90-minute cabinet?**

The number in the type designation is the length of time the cabinet protects its contents from an external fire when tested to EN 14470-1. A 90-minute cabinet has heavier insulation in its walls and doors, so it allows more time for evacuation and firefighting. Type 30 is chosen for smaller quantities of liquid, type 90 where more solvent is stored.

**Does a chemical storage cabinet have to be connected to ventilation?**

The cabinets have air ducts ready for connection to an extraction system, and the model data sheets state the recommended air volume. The connection removes vapours from the interior, so they do not escape when the doors are opened. Whether it is necessary is determined by the risk assessment for the substances stored. Where the room has no duct, the solution is a ventilated chemical cabinet with its own carbon filter.

**Where should acids and alkalis be stored?**

Acids and alkalis are stored in a chemical storage cabinet for non-flammable substances that complies with EN 16121, with a corrosion-resistant interior and spill trays. Acids should not stand on the same shelf as alkalis, and ideally the two are separated into different compartments. We describe the requirements for this type of cabinet in our article [acid and alkali cabinet: requirements](https://www.renggli.pl/en/blog/acid-and-base-cabinet-requirements).

**What does the EN 14470-1 standard cover?**

EN 14470-1 is the European standard for fire-resistant safety storage cabinets for flammable liquids. It defines the fire resistance types (15, 30, 60 and 90 minutes), the furnace test method for the cabinet, automatic door closing in a fire and the closure of the air ducts. Gas cylinder cabinets are covered by the second part of the standard, EN 14470-2. Cabinets for acids and alkalis have no fire resistance and meet the storage furniture standards EN 16121 and EN 16122.

**How do you choose a solvent cabinet and what should you look for in the documentation?**

Solvents require a fire-resistant safety storage cabinet to EN 14470-1, of a type matched to the quantity of liquid and the room. In the documentation, check the fire resistance type on the rating plate, the standard number, the capacity of the spill sump and the recommended air extraction rate. We explain how to match a cabinet to the type of reagent in our guide to choosing [laboratory reagent cabinets](https://www.renggli.pl/en/blog/laboratory-reagent-cabinets-selection).

**How should reagents be stored correctly in a laboratory?**

Reagents are separated by hazard: flammable liquids go in a fire-resistant safety storage cabinet, acids and alkalis in a chemical storage cabinet for non-flammable substances, and volatile substances in a ventilated chemical cabinet. Containers are placed in spill trays, labelled and kept away from heat sources. We have gathered the detailed rules in our article on how to [store chemical reagents](https://www.renggli.pl/en/blog/how-to-store-chemical-reagents-properly-in-the-laboratory).