Knowledge base
Laboratory glossary: UK and US terms explained
Short definitions of the terms used when planning and specifying a laboratory, from fume cupboards and face velocity to benching, worktops and chemical storage. Where British and American usage differ both names are given (fume cupboard and fume hood, worktop and countertop, benching and casework), with standards cited as EN or BS EN and a link to the article that covers each topic in depth.
A
- Acid and alkali cabinet
- Also called: corrosives cabinet, acid cabinet, acid and base cabinet (US)
- An acid and alkali cabinet has a corrosion-resistant interior, for example polypropylene, with separate compartments so that acids and alkalis are kept apart, and can usually be connected to an extract. Separation prevents a reaction if something leaks, and ventilation limits corrosion from fumes.
- More: Acid and base cabinet - what features should it have?
- Activated carbon filter
- Also called: carbon filter, charcoal filter
- An activated carbon filter is a cartridge of activated carbon that captures vapours, mostly of organic compounds, by adsorption on the carbon surface. The carbon grade is matched to the substances in use and a saturated filter must be replaced, which is why a ductless fume cupboard needs a chemical list and saturation monitoring.
- More: Carbon filter fume hood or extraction type?
- Air change rate
- Also called: air changes per hour (ACH), ventilation rate
- Air change rate is the number of times per hour the ventilation replaces the whole volume of air in a room: airflow in m³/h divided by room volume in m³. In a laboratory it follows from the extract that fume cupboards and ventilated cabinets need, occupational hygiene requirements and heat gains, and is fixed in the ventilation design.
- More: Why is laboratory ventilation crucial for staff safety?
- Anti-vibration table
- Also called: vibration isolation table, anti-vibration bench
- An anti-vibration table isolates an instrument from building vibration through the mass of its top and damping elements such as elastomer or pneumatic mounts. It is used for microscopes, high-resolution balances and optical setups, and how well it works depends on the vibration frequencies present at the site.
- More: Anti-vibration table: how to choose the design and protect the measurement
C
- C-frame and H-frame
- Also called: C-leg frame, cantilever frame, H-leg frame
- C-frame and H-frame are two ways of supporting a laboratory bench worktop. A C-frame has legs at the back only and cantilevered arms under the top, leaving the front open, while an H-frame stands on front and back legs joined by a crossbar. The choice depends on whether the space under the worktop should stay free for mobile cabinets and knee room or will hold fixed cabinets.
- More: Construction systems C-frame and H-frame - analysis of applications and impact on laboratory functionality
- Chemical resistance
- Also called: chemical resistance table, chemical spot test
- Chemical resistance is the ability of a surface to stay in contact with a reagent for a set time without lasting change such as staining, loss of gloss, swelling or cracking. Manufacturers publish it as tables of reagents, exposure times and ratings; US specifications often refer to the SEFA 3 work surface test, and two tables can only be compared if they used the same method.
- More: Chemical-resistant laboratory furniture - what materials work best?
- Cleanroom chair
- Also called: clean room chair, ESD cleanroom chair
- A cleanroom chair is built to shed as few particles as possible, with smooth sealed surfaces, enclosed mechanisms and materials that do not release fibres. It is chosen for the room's cleanliness class under ISO 14644-1 and, where electronics are handled, for electrostatic protection under EN 61340-5-1.
- Standard: BS EN ISO 14644-1
- More: How to choose a cleanroom chair and meet cleanliness standards
- CLP Regulation and pictograms
- Also called: CLP, GHS pictograms, GB CLP, hazard pictograms
- The CLP Regulation, (EC) No 1272/2008, sets the EU rules for classifying, labelling and packaging chemical substances and mixtures; Great Britain applies its own version, GB CLP. Hazards are shown by 9 pictograms in a red diamond frame, together with a signal word and H and P statements on the label and in the safety data sheet.
- More: Storage of hazardous substances in the laboratory
- Colour coding of laboratory taps
- Also called: color coding (US), media colour coding, service identification colours
- Colour coding of laboratory taps is the system of colours on handles and knobs that tells users which outlet carries water, which gas, compressed air or vacuum; EN 13792 sets it out. It is separate from gas cylinder colours under EN 1089-3, so the same gas can carry different colours on the valve and on the cylinder.
- Standard: BS EN 13792
- More: How to identify media and safely match laboratory taps
D
- Demineralised water
- Also called: deionised water, deionized water (US), DI water, purified water
- Demineralised (deionised) water has most dissolved salts removed by ion exchange, reverse osmosis or distillation, and its purity is usually judged by electrical conductivity. ISO 3696 defines three grades of water for analytical laboratory use (in the US, ASTM D1193 defines reagent water types), and pipework and taps are made from materials that do not release ions into it.
- Standard: ISO 3696
- More: How to choose and design valves for demineralized water?
- Ducted fume cupboard
- Also called: ducted fume hood (US), extraction fume cupboard
- A ducted fume cupboard is connected by ductwork to an extract system that discharges contaminated air outside the building. The fan, duct run and make-up air are designed with the building, because the cupboard only performs as in its type test when it receives the extract airflow stated by the manufacturer.
- More: Ducted fume hood
- Ductless fume cupboard
- Also called: ductless fume hood (US), recirculating filtration fume cabinet, filtration fume cupboard
- A ductless fume cupboard cleans the extracted air through filters, usually activated carbon, and returns it to the room, so it needs no extract duct. It suits work with a known list of substances that the chosen filter can retain; EN 17242 covers these cabinets, while ducted fume cupboards fall under EN 14175.
- Standard: EN 17242
- More: Carbon filter fume hood or extraction type?
E
- EN 13150
- Also called: BS EN 13150, laboratory workbench standard
- EN 13150 is the European standard for laboratory workbenches, giving their dimensions, safety requirements and test methods, including stability and strength, and is published in the UK as BS EN 13150. It covers benches as furniture; fume cupboards fall under EN 14175 and safety storage cabinets under EN 14470.
- Standard: BS EN 13150
- More: EN 13150: editions and how to check table compliance
- EN 14470-1
- Also called: BS EN 14470-1, fire safety storage cabinet standard
- EN 14470-1 is the European standard for safety storage cabinets for flammable liquids, setting construction requirements and the fire resistance test, and is published in the UK as BS EN 14470-1. It classifies cabinets as type 15, 30, 60 or 90 by the number of minutes the internal temperature stays within the permitted rise in the fire test.
- Standard: BS EN 14470-1
- More: Flammable storage cabinet: which type to choose?
- Epoxy resin
- Also called: epoxy worktop, epoxy resin countertop (US), epoxy sink
- Epoxy resin is a chemically cured material cast into one-piece laboratory worktops and sinks, usually with a mineral filler. It resists many acids and solvents and a sink can be cast together with the worktop without a joint; it is heavy and copes less well than ceramic with prolonged high heat.
- More: Epoxy resin worktop - properties, resistance and care
- Exhaust air volume flow
- Also called: extract airflow, exhaust volume, exhaust flow rate (cfm, US)
- Exhaust air volume flow is the volume of air the extract system removes from a fume cupboard per unit of time, stated in m³/h (in the US in cubic feet per minute, cfm). The manufacturer gives it for a specific model and sash opening, and the ventilation designer has to provide it in the building together with matching make-up air.
- More: Why is proper fume hood ventilation so important?
F
- Face velocity
- Also called: inflow velocity, sash opening velocity
- Face velocity is the average speed of air entering a fume cupboard through the open sash, measured across the opening in m/s (in the US often in feet per minute). The EN 14175 series sets no single required value: containment measured under EN 14175-3 shows whether the cupboard protects the user, and face velocity is one of the conditions of that test.
- Standard: BS EN 14175-3
- More: Fume hood efficiency - how to calculate the proper airflow?
- Flammable liquids
- Also called: flammables, highly flammable liquids
- Flammable liquids are liquids with a flash point of not more than 60 °C under the CLP Regulation (GB CLP in Great Britain), split into three categories with hazard statements H224, H225 and H226. In the UK their storage falls under DSEAR, with practical guidance in HSE's HSG51.
- More: Flammable storage cabinet: which type to choose?
- Fume cupboard
- Also called: fume hood (US), laboratory fume hood, chemical fume hood
- A fume cupboard (in the US, a fume hood) is a ventilated laboratory enclosure with a movable sash that draws air away from the user, so vapours and aerosols stay inside. Requirements and test methods are set out in the EN 14175 series, published in the UK as BS EN 14175.
- Standard: BS EN 14175
- More: What is a fume cupboard (fume hood) and how does it work?
G
- Gas cylinder cabinet
- Also called: gas bottle cabinet, gas cylinder safety cabinet
- A gas cylinder cabinet is a fire-resistant, ventilated cabinet for storing and using compressed gas cylinders indoors, with cylinder restraints and entry points for gas lines. EN 14470-2 (BS EN 14470-2 in the UK) classifies these cabinets as type G15, G30, G60 or G90 by fire resistance in minutes.
- Standard: BS EN 14470-2
- More: Gas Cylinder Cabinets for Technical Gases - Safety and Ventilation Requirements
- Gas cylinder colour coding
- Also called: gas cylinder colours, gas bottle colours, cylinder shoulder colour
- Gas cylinder colour coding uses the colour of the cylinder shoulder to show the gas's main hazard (flammable, oxidising, inert, or toxic and/or corrosive), following EN 1089-3, published in the UK as BS EN 1089-3. Some common gases have their own shoulder colour, such as white for oxygen, but the label, not the colour, identifies the contents.
- Standard: BS EN 1089-3
- More: Gas cylinder colours: the shoulder shows the hazard
- Good Manufacturing Practice (GMP)
- Also called: GMP, EU GMP, Orange Guide
- Good Manufacturing Practice (GMP) is the set of requirements for making medicinal products to a consistent quality; in the EU it is set out in EudraLex Volume 4, and in the UK the MHRA publishes it in the Orange Guide. For laboratory fit-out it means surfaces that are easy to clean, materials that withstand disinfectants and furniture matched to the cleanroom grade of each room.
- More: Pharmaceutical laboratory equipment - GMP requirements and furniture selection
H
- HPL laminate
- Also called: high-pressure laminate, laminate worktop, laminate countertop (US)
- HPL (high-pressure laminate) is a sheet or facing made of resin-impregnated paper layers pressed under high pressure; EN 438 sets out its requirements and tests. In a laboratory it suits dry work and mild reagents, and chemical resistance depends on the surface layer, not on the label HPL itself.
- Standard: BS EN 438
- More: Ceramic worktop vs. HPL laminate - comparison in terms of chemical resistance
I
- Island bench and wall bench
- Also called: island bench, peninsula bench, perimeter bench, wall bench
- An island bench stands free in the room and can be worked from two or more sides, while a wall bench (perimeter bench) runs along a wall where the services usually are; a peninsula bench is joined to the wall at one end. The layout drives how services reach each bench, how wide the aisles are and how many workplaces the room holds.
- More: Island laboratory bench or wall bench: how to choose
L
- Laboratory accreditation
- Also called: ISO/IEC 17025 accreditation, UKAS accreditation
- Laboratory accreditation is formal recognition by a national accreditation body, in the UK the United Kingdom Accreditation Service (UKAS), that a testing or calibration laboratory meets ISO/IEC 17025. The standard covers the laboratory's competence and way of working, and furniture and fit-out affect it only indirectly, for example through environmental conditions during measurement.
- Standard: ISO/IEC 17025
- More: ISO standards for laboratories - how does equipment affect certification?
- Laboratory furniture system
- Also called: laboratory benching (UK), lab casework (US), laboratory casework
- A laboratory furniture system is a range of compatible parts (frames, worktops, cabinets, shelving and service routing) from which benches of different sizes and layouts are built. UK specifiers usually call the result laboratory benching and US specifiers lab casework; EN 13150, published in the UK as BS EN 13150, covers bench dimensions and safety requirements.
- Standard: BS EN 13150
- More: Laboratory furniture
- Laboratory sink
- Also called: lab sink, laboratory basin, cup sink
- A laboratory sink is a basin made of a reagent-resistant material such as ceramic, epoxy resin, polypropylene or stainless steel, set into the worktop or cast in one piece with it. It is chosen for the reagents in use, the size of the glassware washed in it and how the waste water is drained, including any neutraliser.
- More: Laboratory sink: how to choose the size and design the chamber depth?
- Laboratory stool
- Also called: lab stool, standing-height stool
- A laboratory stool is a height-adjustable seat without a backrest or with a small one, used at high benches and at instruments where the user often stands up. Its surfaces must withstand cleaning and disinfection, and a foot ring or footrest is needed when the seat is set high.
- More: Laboratory stool - when does it work better than a chair?
- Laboratory taps and valves
- Also called: laboratory fittings, laboratory faucets (US), gas cocks, service outlets
- Laboratory taps and valves are the outlets for water, technical gases, compressed air and vacuum fitted to worktops, service spines and fume cupboards. They differ from sanitary fittings in their media colour coding to EN 13792 and in being built for the medium they carry, such as deionised water or high-purity gases.
- Standard: BS EN 13792
- More: Laboratory fittings - types of valves, gases and media in laboratory equipment
- Laboratory technical design
- Also called: laboratory planning, lab programming (US), room data sheets
- Laboratory technical design describes the work done in a laboratory and derives from it the room layout, workplaces, equipment and service requirements, often recorded in room data sheets. It comes before the building services design, because it supplies its inputs, such as the number of fume cupboards and the services each bench needs.
- More: What is the development of a technological design for a laboratory?
- Laboratory workstation ergonomics
- Also called: lab ergonomics, laboratory bench ergonomics
- Laboratory workstation ergonomics means matching worktop and seat height, reach, lighting and equipment layout to the person and the task, to limit awkward postures and repetitive strain. Worktop height depends on whether the work is done seated or standing, and EN 13150 gives dimensions for laboratory benches.
- Standard: BS EN 13150
- More: Workplace arrangement in the laboratory - ergonomics and space organization
- Laboratory zoning
- Also called: containment level, clean and dirty zones, biosafety level (US)
- Laboratory zoning divides rooms or parts of rooms by type of work and hazard, for example into clean and dirty zones or areas for biological and chemical work, with controlled passage between them. For biological agents the zones follow containment levels 2 to 4, which Directive 2000/54/EC sets for agents in hazard groups 2 to 4; Great Britain applies them through COSHH and ACDP guidance, and the US uses biosafety levels.
- More: Biomedical engineering laboratories - how to safely integrate the biological research zone with the equipment testing area?
- Laminar flow cabinet
- Also called: laminar flow hood, clean bench, laminar airflow cabinet
- A laminar flow cabinet (clean bench) blows HEPA-filtered air in a steady, uniform stream across the work surface to keep the sample free of contamination from the room. It does not protect the operator: work with biological agents needs a microbiological safety cabinet to EN 12469, and work with chemical vapours needs a fume cupboard.
- More: Laminar flow chamber - what is it, how does it work and where is it used?
- Local exhaust arm
- Also called: extraction arm, snorkel, fume extraction arm
- A local exhaust arm captures fumes close to their source, for example above an instrument or a balance, without enclosing the work. It gives less protection than a fume cupboard because there is no enclosure or sash; in Great Britain it counts as local exhaust ventilation (LEV) and falls under the COSHH examination duty.
- More: Laboratory extractor and fume hood - what is the difference and what to choose?
M
- Modular laboratory furniture
- Also called: modular benching, flexible lab furniture, mobile benching
- Modular laboratory furniture is built from repeating units of fixed size that can be added, moved or swapped without rebuilding a whole bench. It is often combined with mobile cabinets and services fed from above, so the lab layout can change as the work changes.
- More: Modular Laboratory Furniture - Flexibility and Adaptation of the Research Space
- Monolithic ceramic
- Also called: ceramic worktop, ceramic countertop (US), fired ceramic
- Monolithic ceramic is a worktop and sink material fired as a single solid piece, uniform through its thickness and finished with a glaze. It withstands high temperatures and most chemicals, but it is heavy, can crack on impact, and hydrofluoric acid and hot concentrated alkalis attack the glaze.
- More: Ceramic worktop vs. HPL laminate - comparison in terms of chemical resistance
O
- On-site test
- Also called: in-situ test, commissioning test, thorough examination and test (LEV)
- An on-site test checks an installed fume cupboard in the room where it is used, following EN 14175-4, to show that it performs as in its type test with the building's real ventilation. It is done at commissioning and then periodically; in Great Britain COSHH regulation 9 requires local exhaust ventilation, fume cupboards included, to be thoroughly examined and tested at least every 14 months.
- Standard: BS EN 14175-4
- More: Fume Hood Maintenance and Inspections - How to Maintain Efficiency and Safety?
P
- Perchloric acid fume cupboard
- Also called: perchloric acid fume hood (US), wash-down fume cupboard
- A perchloric acid fume cupboard has a wash-down system that rinses the interior and the exhaust duct, and is built from acid-resistant materials with no organic parts where perchlorates could build up. Perchlorate deposits can explode on impact or heating, so hot perchloric acid digestions are not done in a standard fume cupboard.
- More: Perchloric acid fume hood - special design requirements
- Phenolic resin
- Also called: phenolic worktop, compact phenolic, phenolic resin countertop (US)
- Phenolic resin worktops are solid panels of paper layers impregnated with phenolic resin and pressed under heat and high pressure (compact laminate), in laboratory grades often with an electron-beam cured surface. They are lighter than ceramic and resist moisture and many chemicals, but tolerate less heat.
- More: Phenolic resin: properties and use in the laboratory
- Polypropylene
- Also called: PP, polypropylene sink
- Polypropylene (PP) is a thermoplastic welded into sinks, trays and the linings of acid and alkali cabinets because it withstands most acids, alkalis and salt solutions. It softens at high temperatures, so hot vessels should not be placed on it, and it does not tolerate some organic solvents.
- More: Ceramic, steel or resin laboratory sink - which material to choose?
Q
- Quartz composite
- Also called: engineered stone, quartz-granite composite, quartz worktop
- Quartz composite is a worktop material made of quartz aggregate bound with resin and pressed into slabs with a hard, non-absorbent surface. It resists scratching and many reagents, but resistance to specific chemicals and heat depends on the resin, so it is checked against the manufacturer's chemical resistance table.
- More: Laboratory Worktops in Practice: An Overview of Materials and Their Chemical Resistance
S
- Safety shower and eyewash
- Also called: emergency shower, eyewash station, drench shower
- A safety shower and an eyewash unit flush the body or eyes with water immediately after contact with a hazardous substance. In Europe plumbed laboratory body showers are covered by EN 15154-1 and plumbed eyewash units by EN 15154-2 (BS EN 15154 in the UK); in the US the reference is ANSI/ISEA Z358.1.
- Standard: BS EN 15154
- More: Safety showers and laboratory eyewashes - requirements and placement
- Safety storage cabinet
- Also called: flammables cabinet, fire safety storage cabinet, type 90 cabinet
- A safety storage cabinet is a fire-resistant cabinet for keeping flammable liquids in a workroom, which protects its contents from igniting for a set time in a fire. The type gives that time in minutes under EN 14470-1, for example type 30 or type 90.
- Standard: BS EN 14470-1
- More: Laboratory cabinet: how to interpret markings and choose a class
- Sash
- Also called: fume cupboard sash, sash window, vertical sash
- The sash is the movable glazed front of a fume cupboard; lowering it shrinks the working opening and shields the user's face from splashes. Sashes can be vertical, horizontal or combined, and EN 14175-3 tests are run at defined sash positions, so how far it is raised in daily use matters.
- Standard: BS EN 14175-3
- More: Laboratory Fume Hood and Workplace Safety - What to Pay Attention To
- Service spine
- Also called: utility spine, service bridge, ceiling service module, service column
- A service spine is a structure above or beside a bench that carries services (power, gases, water, data) and brings them to outlets at the workplace. Suspended above the bench it is often called a service bridge or ceiling service module, and feeding services this way lets benches be moved without breaking into the floor.
- More: Laboratory Benches with Utilities - How to Plan Services?
- Stainless steel
- Also called: stainless steel worktop, stainless steel countertop (US)
- Stainless steel is an iron alloy with at least 10.5% chromium, which forms a thin oxide layer on the surface that protects it from corrosion; grades are listed in EN 10088. On laboratory and clinical worktops it is valued for easy cleaning, disinfection and heat resistance, but chlorides and some acids, such as hydrochloric acid, can corrode it.
- Standard: BS EN 10088
- More: Stainless steel worktops in the laboratory - when are they the best choice?
T
- Technical gases
- Also called: laboratory gases, specialty gases, industrial gases
- Technical gases are the gases a laboratory uses to supply instruments and processes, such as nitrogen, argon, helium, hydrogen, oxygen, carbon dioxide and compressed air, delivered from cylinders or a central supply. The installation covers the gas source, regulators, pipework and outlets, and its design accounts for whether each gas is flammable, oxidising or toxic.
- More: Technical gas installations - design, installation and standards
- Tender award criteria
- Also called: MEAT, most advantageous tender (MAT), quality-price ratio
- Tender award criteria are the rules a contracting authority uses to compare bids and choose the winner; besides price they can cover delivery time, warranty, technical merit or running costs. Under the UK Procurement Act 2023 contracts go to the most advantageous tender (MAT), the successor to the EU term most economically advantageous tender (MEAT).
- More: Laboratory furniture tender: what to score beyond price
- Treatment room
- Also called: clinical treatment room, procedure room
- A treatment room is a clinical room for injections, dressings, blood sampling and minor procedures, usually with a clinical wash-hand basin, a clean preparation worktop and space for clinical waste. In England, NHS guidance HBN 00-03 sets out typical layouts and equipment for such rooms.
- More: Treatment room equipment step by step - furniture, materials and certificates
- Type test
- Also called: fume cupboard type test, type testing
- A type test is a series of tests on one fume cupboard in a test laboratory under EN 14175-3 (BS EN 14175-3 in the UK), and its result applies to that model built the same way. It covers containment at the inner and outer measurement planes, robustness of containment against disturbances, air exchange inside the cupboard and pressure drop.
- Standard: BS EN 14175-3
- More: Laboratory furniture standards and fume cupboard certificates
V
- Variable air volume (VAV)
- Also called: VAV fume cupboard, VAV control
- Variable air volume (VAV) control adjusts how much air is extracted from a fume cupboard according to sash position, so the velocity through the opening stays constant. With the sash lowered the system extracts less air, which cuts the energy spent on ventilation; EN 14175-6 covers VAV fume cupboards.
- Standard: BS EN 14175-6
- More: Why is proper fume hood ventilation so important?
- Ventilated cabinet
- Also called: ventilated chemical cabinet, ventilated storage cabinet
- A ventilated cabinet is connected to an extract that removes vapours given off by chemical containers before they reach the room. It is used for volatile, corrosive or odorous substances; for flammable liquids it does not replace a safety storage cabinet, because it is not fire-resistant.
- More: Ventilated chemical cabinet - when is it needed?
W
- Wastewater neutraliser
- Also called: pH neutralisation system, neutralization tank (US), acid neutralisation unit
- A wastewater neutraliser brings the pH of laboratory waste water into the range accepted by the sewer operator before discharge, by dosing acid or alkali or by passing it through a neutralising bed. The limits come from the discharge permit; in the UK that is the trade effluent consent issued by the water company.
- More: Laboratory wastewater neutralizers: how to choose and meet the requirements
- Weighing table
- Also called: balance table, balance bench, anti-vibration weighing table
- A weighing table (balance table) holds an analytical or precision balance on a measuring slab separated from the rest of the frame, so vibrations from resting arms or nearby work do not disturb the reading. The slab is usually heavy, often stone, and sits on its own base or on damping elements.
- More: How to choose a weighing table for a laboratory? 10 parameters worth checking before buying